Alcatel-Lucent IAP93 Betriebsanweisung Seite 72

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 335
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 71
72 | Initial Configuration Tasks AOS-W Instant 6.3.1.1-4.0 | User Guide
2. Enter the HTTP proxy server's IP address and the port number.
3. If you do not want the HTTP proxy to be applied for a particular host, click New to enter that IP address or domain
name of that host under exceptions list.
In the CLI
(Instant Access Point)(config)# proxy server 192.0.2.1 8080
(Instant Access Point)(config)# proxy exception 192.0.2.2
(Instant Access Point)(config)# end
(Instant Access Point)# commit apply
Upgrading an OAW-IAP Using Automatic Image Check
You can upgrade an OAW-IAP by using the automatic image check feature. The Automatic image checks are
performed once after the AP boots up and every week thereafter.
If the image check locates a new version of the AOS-W Instant software on the image server, the New version
available link is displayed at the top right corner of the AOS-W Instant UI.
If OmniVista is configured, the automatic image check is disabled.
To check for a new version on the image server in the cloud:
1. Go to Maintenance>Automatic>Check for New Version. After the image check is completed, one of the
following messages is displayed:
n No new version available If there is no new version available.
n Image server timed out Connection or session between the image server and the OAW-IAP is timed out.
n Image server failure If the image server does not respond.
n A new image version found If a new image version is found.
2. If a new version is found, the Upgrade Now button becomes available and the version number is displayed.
3. Click Upgrade Now.
The OAW-IAP downloads the image from the server, saves it to flash and reboots. Depending on the progress
and success of the upgrade, one of the following messages is displayed:
n Upgrading While image upgrading is in progress.
n Upgrade successful When the upgrading is successful.
n Upgrade failed When the upgrading fails.
If the upgrade fails and an error message is displayed, retry upgrading the OAW-IAP.
Upgrading to a New Version Manually
If the automatic image check feature is disabled, you can use obtain an image file from a local file system or from a
TFTPor HTTP URL. To manually check for a new firmware image version and obtain an image file:
1. Navigate to Maintenance>Firmware. The Firmware window is displayed.
2. Under Manual section, perform the following steps:
l Select the Image file option. This method is only available for single-class OAW-IAPs.
The following examples describe the image file format for different OAW-IAP models:
n For OAW-IAP134/135 AlcatelInstant_Cassiopeia_6.3.1.1-4.0.0.0_xxxx
n For OAW-RAP108/109 and OAW-IAP114/115 AlcatelInstant_Pegasus_6.3.1.1-4.0.0.0_xxxx
n For OAW-RAP155/155P AlcatelInstant_Aries_6.3.1.1-4.0.0.0_xxxx
n For OAW-IAP220 Series— AlcatelInstant_Centaurus_6.3.1.1-4.0.0.0_xxxx
Seitenansicht 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 334 335

Kommentare zu diesen Handbüchern

Keine Kommentare